xrdelectro

DIP switches and debug modes

When done, remember to return all DIPs Off (switches being in the position closer to module center), otherwise this will interfere with normal operation.

DIP switch Location

DIP switches are located under OLED. To access them, OLED needs to be slid out: Press down the plastic clip against the board (clip is located nearest the longer board edge, where USB socket is located) and while holding it, slide the OLED up.

These DIP switches let enable different test modes; and you should be able to power the OLED separately with a micro USB cable plugged into it. Though, it might be of limited use, if it’s hard to access or more trouble to access OLED panel to be slid out.

Though, if you actually find use for DIP switches — after adjusting, remember to turn off all the debug DIP switches (4-7), otherwise test mode will interfere with the normal functioning.

Use for troubleshooting

If it happens that after soldering module in and powering on the device you do not get anything on the OLED

  1. Do a quick visual check of all the solder joints - all should have nice fillets, as well as no excess solder (possibly short-circuiting/bridging something).
  2. If everything seems right, next you should check if the OLED panel itself is working by:

If that does not help, you either have a broken OLED panel or the board has some fault.

  1. If display is working, then:

You might be able to use USB-power (in DIP-4 debug mode) + DMM in diode mode to test, that all the signal from motherboard is received in the OLED module.

In the worst case, you just send me your module and I will try to fix it.